{"id":4689,"date":"2025-03-27T16:19:14","date_gmt":"2025-03-27T08:19:14","guid":{"rendered":"https:\/\/chi-swear.com\/?p=4689"},"modified":"2025-03-27T16:23:05","modified_gmt":"2025-03-27T08:23:05","slug":"customer-requested-4","status":"publish","type":"post","link":"https:\/\/chi-swear.com\/de\/customer-requested-4\/","title":{"rendered":"Die Verdrahtungsmethode (2 AC-Eing\u00e4nge, 2 AC-Ausg\u00e4nge) unterscheidet sich von unserer standardm\u00e4\u00dfigen 3-Draht-Verdrahtungsmethode f\u00fcr Fotozellen."},"content":{"rendered":"<p class=\"wp-block-paragraph\">(Customer &#8211; Requested)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">    Here We Explain in Detail the Differences between the Two, the Specific Meaning of the Customer&#8217;s Wiring Method and the Reasons Behind It:<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">I. Our Standard 3 &#8211; Wire Wiring Method of Photocell (ANSI Standard)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The ANSI &#8211; standard wiring method commonly used for our Long &#8211; Join photocell products consists of 3 wires:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Drahtfarbe<\/th><th>Function Description<\/th><th>Wiring Terminal<\/th><\/tr><\/thead><tbody><tr><td>Schwarz<\/td><td>Power Input (Line)<\/td><td>Connect to the live wire of the power supply<\/td><\/tr><tr><td>Wei\u00df<\/td><td>Neutral Line (Neutral)<\/td><td>Connect to the neutral wire of the power supply<\/td><\/tr><tr><td>Rot<\/td><td>Output Load Wire (Load)<\/td><td>Connect to the live wire of the load (lighting fixture)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"643\" src=\"http:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/nema-socket-Wiring-Diagram-1024x643.png\" alt=\"\" class=\"wp-image-4693\" srcset=\"https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/nema-socket-Wiring-Diagram-1024x643.png 1024w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/nema-socket-Wiring-Diagram-300x189.png 300w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/nema-socket-Wiring-Diagram-768x483.png 768w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/nema-socket-Wiring-Diagram-600x377.png 600w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/nema-socket-Wiring-Diagram.png 1028w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"820\" src=\"http:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/photocontrol-with-receptacle-1024x820.jpg\" alt=\"\" class=\"wp-image-4677\" srcset=\"https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/photocontrol-with-receptacle-1024x820.jpg 1024w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/photocontrol-with-receptacle-300x240.jpg 300w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/photocontrol-with-receptacle-768x615.jpg 768w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/photocontrol-with-receptacle-600x481.jpg 600w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/photocontrol-with-receptacle.jpg 1326w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In this standard wiring method, the input and output share one neutral wire (the white Neutral wire).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">II. Customer &#8211; Requested  &#8211; Wire Wiring Method (Black for Li, White for N; Red for Lo, White for N)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The customer&#8217;s wiring method uses 4 wires and is a &#8220;completely separated input &#8211; output&#8221; wiring method:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Drahtfarbe<\/th><th>Function Description<\/th><th>Wiring Terminal<\/th><\/tr><\/thead><tbody><tr><td>Schwarz<\/td><td>Input Live Wire (Line In)<\/td><td>Connect to the live wire input of the AC power supply (Li)<\/td><\/tr><tr><td>Wei\u00df<\/td><td>Input Neutral Wire (Neutral In)<\/td><td>Connect to the neutral wire input of the AC power supply (Ni)<\/td><\/tr><tr><td>Rot<\/td><td>Output Live Wire (Line Out)<\/td><td>Output to the live wire of the load (Lo)<\/td><\/tr><tr><td>Wei\u00df<\/td><td>Output Neutral Wire (Neutral Out)<\/td><td>Output to the neutral wire of the load (No)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">This method is called &#8220;complete input &#8211; output isolation&#8221;, meaning that the live and neutral wires of the input and output ends are completely independent and not shared.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">III. Specific Differences<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Specific Difference Points<\/th><th>Our Commonly Used 3 &#8211; Wire Method<\/th><th>Customer&#8217;s 4 &#8211; Wire Isolation Method<\/th><\/tr><\/thead><tbody><tr><td>Neutral Wire (N)<\/td><td>Shared for input and output<\/td><td>Independently separated for input and output<\/td><\/tr><tr><td>Sicherheit<\/td><td>General safety<\/td><td>Higher safety level<\/td><\/tr><tr><td>Anwendungsszenarien<\/td><td>Conventional outdoor lighting, simple streetlights<\/td><td>More rigorous outdoor public lighting projects<\/td><\/tr><tr><td>Installationskomplexit\u00e4t<\/td><td>Simple and easy to wire<\/td><td>Slightly more complex, with one additional neutral wire<\/td><\/tr><tr><td>Difference in Product Internal Structure<\/td><td>Can be controlled by a simple single &#8211; pole single &#8211; throw relay<\/td><td>Requires additional wiring terminals or a dedicated relay inside<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">IV. Reasons Why Customers Adopt the 4 &#8211; Wire Method of photocell<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Customers specifically request the 4 &#8211; wire (2 inputs + 2 outputs) wiring method usually for the following reasons:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Higher Safety Requirements:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Regulations in some countries or regions where customers are located require that the input and output circuits must be completely isolated.<\/li>\n\n\n\n<li>Isolating the input and output circuits can avoid equipment damage or electric shock risks caused by neutral wire breakage or misconnection.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. Higher Reliability and Equipment Protection:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The completely separated input &#8211; output wiring method is conducive to providing better electrical protection.<\/li>\n\n\n\n<li>In case of a fault, it is easier to detect and determine the problem, and clarify the responsibility.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">3. Specific Certification Requirements:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Customers may specifically require the use of this input &#8211; output isolation scheme when applying for certain high &#8211; level safety certifications (such as specific UL certification standards in North America or government\/municipal streetlight project specifications) to meet specific certification requirements.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">4. Avoiding Problems Caused by Sharing the Neutral Wire:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>For example, in large &#8211; scale public lighting systems, unbalanced neutral wire loads or voltage differences may pose potential safety hazards, and the isolated wiring method can effectively avoid such problems.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">V. Why Our Products Currently Use 3 &#8211; Wires <\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Standardization Considerations<\/strong>: Wiring methods with 3 wires are commonly accepted by standards such as ANSI C136.10\/UL773 and have been widely used. The wiring is simple and easy to understand.<\/li>\n\n\n\n<li><strong>Kosten\u00fcberlegungen<\/strong>: The product structure with 3 &#8211; wire wiring is simple. Only a single &#8211; pole single &#8211; throw relay is needed inside, which results in a low cost and makes the product more competitive in the market.<\/li>\n\n\n\n<li><strong>Wide Application Range<\/strong>: The vast majority of markets and customer projects do not strictly require complete isolation. 3 &#8211; wire products are sufficient to meet the needs of most application scenarios.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">However, with the changes in market demands and regulations, for high &#8211; end projects or special customer needs, we may consider launching 4 &#8211; wire completely isolated products in the future to cover more market demands.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">VI. Product Realization Methods (if Customers Must Have 4 &#8211; Wires)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If customers insist on this wiring method, the factory needs to make corresponding adjustments:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Relay Configuration Adjustment<\/strong>: A double &#8211; pole double &#8211; throw relay (DPST Relay) must be used to cut off or connect the live wire and the neutral wire simultaneously.<\/li>\n\n\n\n<li><strong>Internal Circuit Adjustment<\/strong>: The live and neutral wires of the input end enter the input terminals of the relay completely independently, and the output end is then separately output by the relay.<\/li>\n\n\n\n<li><strong>Wiring Terminal Adjustment<\/strong>: Provide independent input and output wiring terminals or wires inside the product.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">VII. Suggestions for Communicating with Customers<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>First, understand the real reasons why customers insist on the 4 &#8211; wire method, and confirm whether it is due to regulatory requirements, project requirements, or customer habits.<\/li>\n\n\n\n<li>Clearly inform customers that the 4 &#8211; wire solution will increase costs compared to the 3 &#8211; wire solution, and the price may rise accordingly.<\/li>\n\n\n\n<li>If customers confirm that they must have 4 &#8211; wires, product adjustment and design can be arranged according to the project volume and long &#8211; term cooperation prospects.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">VIII. Summary (for Sales to Communicate with Customers)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The core of the customer&#8217;s request for the 4 &#8211; wire (2 AC inputs, 2 AC outputs) method is to achieve complete isolation of the input and output circuits, so as to improve the safety and reliability of the product. Our current standard ANSI products use the 3 &#8211; wire method, which is a conventional wiring method with the input and output sharing the neutral wire and has been widely used in the market.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is recommended to clearly communicate with customers about their specific needs and regulatory requirements to determine whether special customization is required or whether to use our existing standardized and mature products.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The above is a detailed description of the differences between the 4 &#8211; wire method and the 3 &#8211; wire method and the reasons behind them. If you have any other questions or need further technical support, please feel free to ask.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"750\" height=\"385\" src=\"https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/zhaga\u63a5\u7ebf.avif\" alt=\"\" class=\"wp-image-4692\" srcset=\"https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/zhaga\u63a5\u7ebf.avif 750w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/zhaga\u63a5\u7ebf-300x154.avif 300w, https:\/\/chi-swear.com\/wp-content\/uploads\/2025\/03\/zhaga\u63a5\u7ebf-600x308.avif 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>(Customer &#8211; Requested) Here We Explain in Detail the Differences between the Two, the Specific Meaning of the Customer&#8217;s Wiring Method and the Reasons Behind It: I. Our Standard 3 &#8211; Wire Wiring Method of Photocell (ANSI Standard) The ANSI &#8211; standard wiring method commonly used for our Long &#8211; Join photocell products consists of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4677,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"footnotes":""},"categories":[53],"tags":[79,77,76,78,80],"class_list":["post-4689","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product-introduction","tag-3pin-wiring","tag-7pin-wiring","tag-nema-socket-wiring-diagram","tag-photocell-wiring","tag-photocontrol-wiring"],"_links":{"self":[{"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/posts\/4689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/comments?post=4689"}],"version-history":[{"count":4,"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/posts\/4689\/revisions"}],"predecessor-version":[{"id":4700,"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/posts\/4689\/revisions\/4700"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/media\/4677"}],"wp:attachment":[{"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/media?parent=4689"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/categories?post=4689"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chi-swear.com\/de\/wp-json\/wp\/v2\/tags?post=4689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}