مخطط تفصيلي
- مقدمة
- What Are the Core Differences in Market Positioning Between JL-204C and UM-204C?
- How Do Rated Voltage and Load Capacity Compare Between JL-204C and UM-204C مفاتيح الخلايا الضوئية?
- How Do Power Consumption and Operating Light Levels Differ?
- What Are the Key Technical Parameters of JL-204C vs UM-204C?
- Which Markets and Applications Is UM-204C مفتاح مستشعر الضوء Best Suited For?
- What Factors Build Customer Trust in Long-Join التحكم الضوئي الحلول؟
- أيّ وعاء التحكم الضوئي Should You Choose Based on Performance and Market Needs?
- الكلمات النهائية
اختيار الصحيح التحكم الضوئي is not just about price. It is about extended reliability, where the product will be used. JL-204C and UM-204C serve very different market needs.
One focuses on higher performance and stricter requirements. The other targets are cost-sensitive regions with flexible certification needs.
This comparison helps you decide which model fits your project best.

What Are the Core Differences in Market Positioning Between JL-204C and UM-204C?
JL-204C مستشعر الخلية الضوئية targets markets where independent safety certification matters. These regions (like North America and parts of South America) require يو ال/المعهد الوطني للمعايير الأمريكية معتمد أجهزة استشعار الضوء for outdoor lighting. A UL mark proves weather readiness and long-term reliability.
UM-204C خلية ضوئية ضوئية, in contrast, is built for price-sensitive zones where certification isn’t mandatory. It still meets electrical performance norms but doesn’t carry UL marks. This lowers cost without sacrificing basic dusk-to-dawn switching capability.
Performance vs cost focus:
- JL-204C suits regulated tenders where high reliability is expected.
- UM-204C suits emerging markets and budget projects.
Typical scenarios
- JL-204C for city lighting contracts needing certified gear.
- UM-204C for standard outdoor fixtures where price matters more than formal listings.
How Do Rated Voltage and Load Capacity Compare Between JL-204C and UM-204C مفاتيح الخلايا الضوئية?
Both products share a wide input range, including:
- 120–277 VAC
- 50/60 Hz support
Both handle typical outdoor lighting voltages well. However, their load capabilities differ significantly.
Load Capacity Comparison:
- JL-204C مستشعر إضاءة الخلية الضوئية supports higher loads that match robust street luminaires. Load details include:
- up to 1000 W incandescent
- 1800 VA ballast
- 8 A @ 120 VAC and 5 A @ 208-277 VAC electronic ballast capability
- The UM-204C مفتاح الخلية الضوئية لمستشعر الضوء is suitable for medium and standard outdoor fixtures. Load capacity is rated:
- 500 W incandescent
- 850 VA ballast, with 5 A e-ballast
Practical Implications:
JL-204C is better for high-power and strict load environments. It supports heavier lamps without derating. UM-204C fits standard outdoor lighting where loads are moderate and cost efficiency matters.
The table below gives a visual estimate of power savings for JL‑204C vs UM‑204C over one year.
| Photocontrol Model | Power Draw (W) | Hours of Operation/Year | Estimated Annual Energy Use (kWh) |
| JL‑204C | 1.5 | 4,380 (12 h/day × 365 days) | 6.57 kWh |
| UM‑204C | 3 | 4,380 | 13.14 kWh |
How Do Power Consumption and Operating Light Levels Differ?

JL-204C draws about 1.5 W at 120 V. This keeps its standby energy low while monitoring ambient light. UM-204C typically uses around 3 W at 120 V. This is roughly double the JL’s consumption. This means more ongoing energy draw over the years of operation.
Light Threshold Behavior
Both models trigger lights around the same low light range (10–20 lux on). However, JL-204C tends to turn lights off between 30–60 lux, providing a tighter off window. UM-204C’s off-range is wider (30–80 لوكس), meaning lights may stay on longer into daylight.
Impact on Operation
Lower power draw reduces hidden annual energy costs, especially across many fixtures. A narrower off threshold with JL-204C can also cut wasted run-time at dawn, saving electricity and reducing lamp cycling.
What Are the Key Technical Parameters of JL-204C vs UM-204C?
| المعلمة | JL-204C | UM-204C |
| الجهد المقدر | 120-277 فولت تيار متردد | 120-277 فولت تيار متردد |
| نطاق الجهد المطبق | 105-305 فولت تيار متردد | 105-305 فولت تيار متردد |
| التردد المقدر | 50/60 هرتز | 50/60 هرتز |
| الحمل المقدر | 1000 W Tungsten; 1800 VA Ballast; 8 A@120 V / 5 A@208-277 V e-Ballast | 500 W Tungsten; 850 VA Ballast; 5 A e-Ballast |
| استهلاك الطاقة | 1.5 W @ 120 V | ~3 W @ 120 V |
| Turn-On Light Level | 10-20 lux | 10-20 lux |
| Turn-Off Light Level | 30-60 lux | 30-80 lux |
| وضع الفشل | الفشل | الفشل |
| تصنيف الحماية | IP54 / IP65 / IP67 | IP54 / IP65 / IP67 |
| الشهادات | UL, CE, RoHS | (No mandatory UL) |
Which Markets and Applications Is UM-204C مفتاح مستشعر الضوء Best Suited For?
UM-204C is positioned as a cost-effective photocontrol with basic but reliable performance. It does not carry mandatory UL certification, which helps keep the unit price lower for buyers in regions where UL is not required. This makes it a preferred choice in emerging and developing markets.
Ideal Market Environments:
- Emerging and developing regions in Africa and Southeast Asia. This is because cost sensitivity is a priority, and strict regulatory certification isn’t enforced.
- Projects without mandatory UL certification where standard electrical performance is sufficient and local code requirements are met by CE or RoHS listings.
- In budget outdoor lighting installations, such as community parks and basic urban lighting projects. Here budget is a key decision factor, and heavy load capacity is not critical.
What Factors Build Customer Trust in Long-Join التحكم الضوئي الحلول؟
- Multiple حماية الملكية الفكرية levels ensure strong dust and water defense for outdoor use.
- A wide range of international certifications meets strict global quality standards.
- ISO-certified production and strict QC process — consistent manufacturing quality and performance.
- Over 20 years of industry experience — proven track record in lighting control solutions.
- Large production capacity with dedicated assembly and testing areas — supports reliable mass output.
- Advanced sealing and glue-filled waterproof crafts — improve enclosure reliability in harsh environments.
- Surge protection and enhanced environmental resistance — protects against unstable grids and weather effects.
- Customization capability (wiring, plug type, pin count, IP level) — adapts products to specific project needs.
- Fast response time and built-in delay functionality — enhances reliable switching without false triggers.
- Positive global user feedback and partner testimonials — reflect strong real-world satisfaction.
The table showcases various international certifications and why they are critical.
| شهادة | Global Market Coverage | Impact on Project Approval |
| يو ال | North America, parts of South America | Mandatory for tenders, high |
| ANSI C136.10 / C136.41 | Global outdoor lighting systems | Ensures system compatibility |
| م | European Union, Middle East | Legal market entry |
| حظر المواد الخطرة | EU, Asia | Environmental compliance reduces risk |
| لجنة الاتصالات الفيدرالية | أمريكا الشمالية | Reduces electromagnetic interference |
| مخطط CB | 50+ countries | Simplifies international export approval |
| ايزو 9001 | عالمي | Ensures consistent product quality |
أيّ وعاء التحكم الضوئي Should You Choose Based on Performance and Market Needs?
اختيار الصحيح مستشعر تبديل الصورة comes down to performance needs and market demands. Below is clear guidance to help you decide.
When to Choose JL-204C
- Best for regulated markets requiring UL/ANSI compliance for tenders and infrastructure projects.
- Designed for higher load capacity and robust switching in demanding street, highway, and urban lighting.
- Offers precise dusk-to-dawn control with surge resistance and a longer expected lifecycle.
When UM-204C Is the Better Fit
- Ideal for lighting where UL certification is not a must. This is mainly the commercial sector.
- Suitable for limited budget projects like community parks and residential pathways.
- Provides reliable automation with acceptable load performance at a lower cost.
الكلمات النهائية
JL-204C suits high-load, regulated projects, while UM-204C fits cost-sensitive markets needing reliable basic control. Choosing depends on certification needs and specific operating priorities. For dependable sourcing and technical support, تشي-سوير remains a trusted supplier of genuine Long-Join photocontrollers.
الروابط الخارجية
- https://www.ul.com/solutions
- https://www.ansi.org/
- https://en.wikipedia.org/wiki/Lux
- https://www.iec.ch/ip-ratings
- https://europa.eu/youreurope/business/product-requirements/labels-markings/ce-marking/index_en.htm
- https://en.wikipedia.org/wiki/RoHS
- https://en.wikipedia.org/wiki/Federal_Communications_Commission
- https://www.iso.org/standard/62085.html


