The photocontrol JL-401B is applicable to control the garden lighting, passage lighting and doorway lighting automatically in accordance with the ambient natural lighting level. Further, a preset 10-30 seconds time-delay might avoid redundancy operation due to spotlight or lightning during the night time.
Presupuesto
Características
Sensor Separated for flexible allocations inside fixture(JL-401BR only)
3~10s Time-delay preventing redundant turning-off caused byheadlights or lightning
Waterproof Lens
Presupuesto
N.º de modelo
JL-401B
JL-401BR
Voltaje nominal
220~240 VCA
Frecuencia nominal
50/60 Hz
Tipo de sensor
CdS photocell
Carga nominal
6A TUNGSTEN、6A Ballast
Consumo de energía
5W Max.
Niveles de operación
10~20Lx Turn-On / 25~35Lx Turn-Off
Modo de fallo
Fallo
Temperatura ambiente
-40℃ ~ +70℃
Humedad relacionada
96%
Longitud de los cables
AWG#18,AWM1015
Protección contra sobretensiones
40J/1750A (MOV)
Certificaciones
CE.UL.ROHS
Instalación
Disconnect power, place screw thread of the photocontrol in knockout hole and fasten with rubber gasket and lock-nut. Wire according to the diagram in below. Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.
Pruebas iniciales
It is normal for the SWITCH to take fewminutes to turn off when first installed.
Para probar que se “encienda” durante el día, cubra su ojo con un material opaco.
No lo cubra con los dedos porque la luz que pasa a través de ellos puede ser lo suficientemente fuerte como para mantener el interruptor abierto.
La prueba durará aproximadamente 2 minutos.
* El funcionamiento de este interruptor no se ve afectado por el clima, la humedad o los cambios de temperatura.