Street Lighting Installation and LED Dimming: An Illustrative Energy Calculation

Workers beside a road luminaire on an elevated work platform, with a blue control device visible above the lamp.
Installation reference from the supplied company image library. Specific model, location, quantity and measured energy savings are not confirmed.

Street lighting installation reference

The supplied installation photograph shows workers using an elevated work platform beside a road luminaire. A blue control device is visible on top of the luminaire. The photograph illustrates a mounting arrangement; the specific controller model, project location, installed quantity and commissioning date have not been independently confirmed.

Illustrative energy calculation: LED dimming

The following calculation is a separate illustrative scenario based on assumptions presented in the 2019 UMELINK solution brochure, pages 14–15. It is not a measured result from the photographed installation.

Assumptions: 10,000 luminaires, 11 operating hours per day, 365 days per year and an illustrative electricity price of RMB 0.86/kWh. The dimmed case assumes a 70 W average input over those operating hours.

Annual result100 W LED baselineAssumed 70 W average with dimming
Electricity consumption4,015,000 kWh2,810,500 kWh
Electricity costRMB 3,452,900RMB 2,417,030

The calculated annual reduction is 1,204,500 kWh (30%) and RMB 1,035,870. Annual consumption = quantity × average input watts ÷ 1,000 × operating hours. Annual electricity cost = annual consumption × electricity price.

These figures are recalculated from the stated assumptions rather than copied from the brochure’s inconsistent totals. The brochure’s combined 75% claim includes a lamp-replacement comparison and must not be attributed to a receptacle or controller alone.

Applying the example to a project

Actual savings depend on the load, driver dimming response, operating schedule, required illumination, metering boundary and control-system consumption. Confirm electrical compatibility, wiring, orientation and sealing against the applicable installation instructions. Compare measured consumption under equivalent lighting-service conditions before claiming project savings. A receptacle alone does not provide the dimming strategy.

Source: UMELINK SMART LIGHT SOLUTION 2019, pages 14–15 (historical illustrative assumptions; not a current project measurement report). No maintenance-cost or carbon-reduction totals are claimed here.

Explorer Prises et accessoires NEMA, commandes d'éclairage intelligent et FAQ sur la sélection et l'installation.

Facebook
Gazouillement
LinkedIn
WhatsApp
Image de Wang Yi

Wang Yi

Bonjour, je suis l'auteur de cet article. Fort de 15 ans d'expérience dans le secteur de l'éclairage, je suis passionné par l'innovation et les échanges. Rejoignez-moi pour explorer les tendances du secteur et façonner l'avenir ensemble. Illuminons la vie !

Vous êtes les bienvenus pour me suivre

Workers beside a road luminaire on an elevated work platform, with a blue control device visible above the lamp.

Obtenez un devis et laissez un commentaire

Laisser un commentaire

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *

Les dernières nouvelles

Manuel

Contactez-nous

Nous vous enverrons les dernières manuel du système de contrôle d'éclairage intelligent basé sur le cloud

Si vous souhaitez recevoir notre nouveau catalogue et un échantillon gratuit, contactez-nous.