JL-412C(R)
Miniature Improved Electronic Direct Wire-In Photocontrol
JL-412C

JL-412CR

製品概要
The photocontrol JL-412C(R) is applicable to control the passage lighting and doorway lighting automatically in accordance with the ambient lighting level.
This product is designed with electronic circuits. Its quicker response with time delay of 3-10 seconds offers easy-to-test feature, while a miniature profile supports most smaller fixtures.
Further, a preset 3-10 seconds time-delay might avoid redundancy operation due to spotlight or lightning during the night time
この製品は UL LLC に登録されており、照明制御用非産業用光電スイッチ規格 UL773A に準拠しています。.
Its R version provides a separated sensor assembly.

仕様
| モデル番号. | JL-412C | JL-412CR |
| 定格電圧 | 120~277VAC | |
| 利用可能な電圧範囲 | 105~305VAC | |
| 定格周波数 | 50/60Hz | |
| 定格荷重 | 1.2A Tungsten / Ballast | |
| 1A e-Ballast | ||
| 消費電力 | 1W Max. | |
| On-off Levels | 10~30Lx Turn-On / 30~80Lx Turn-Off | |
| 周囲温度 | -40℃~+70℃ | |
| 関連する湿度 | 96% | |
| リード長 | AWG #18, AWM1430 | |
インストール
Disconnect power, place screw thread of the photocontrol in knockout hole and fasten with rubber gasket and lock-nut. Wire according to the diagram in below. Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.

初期テスト
スイッチを初めて取り付けたときは、電源が切れるまでに数秒かかることがありますが、これは正常です。.
日中に「オン」になるかどうかをテストするには、目を不透明な素材で覆います。.
Test will take approximately 1 minutes
注文情報
JL-412C 09 R09 M
JL-412C
09
R09
M
2: lead length
09=09″
カスタマイズ可能
3: Sensor Position
R=sensor separated
Null=sensor on body
9=9″sensor lead length
4: M(option) =UL holographic label