JL-260C Photocontrol Receptacle Installation Reference | Chiang Rai

Installation reference: Chiang Rai, Thailand

The supplied reference photographs show a photocontrol and mating receptacle assembly mounted on a metal pole beside a building in Chiang Rai, Thailand. The reference was supplied under the JL-260C name. JL-260C is a photocontrol receptacle; the exact model of the controller fitted above it has not been independently identified.

The supplied project information confirms a commissioning year of 2026 and installation in two batches of 2,000 pcs and 300 pcs (2,300 pcs in total). The image reference folder is dated 17 July 2026; this file date does not establish the commissioning day. Measured energy savings and operating results have not been provided.

Close-up of a photocontrol and mating receptacle assembly secured to a metal pole in Chiang Rai, Thailand.
Close-up of the installed assembly, bracket and cable entry. JL-260C identifies the receptacle; the fitted controller model is unconfirmed. / Detalle del conjunto instalado, soporte y entrada del cable. JL-260C identifica el receptáculo; el modelo del controlador no está confirmado.
Photocontrol assembly on a metal pole outside a blue building in Chiang Rai, Thailand.
Installation context beside a building in Chiang Rai. / Entorno de instalación junto a un edificio en Chiang Rai.
Pole-mounted photocontrol assembly beside trees in Chiang Rai, Thailand.
Pole-mounted photocontrol assembly and cable arrangement. / Conjunto de fotocontrol montado en poste y disposición del cable.
Street-side pole installation beneath decorative lanterns in Chiang Rai, Thailand.
Chiang Rai, Thailand: street-side installation environment. / Chiang Rai, Tailandia: entorno de instalación junto a la calle.

Illustrative energy calculation: LED dimming

The following calculation is a separate illustrative scenario based on assumptions presented in the 2019 UMELINK solution brochure, pages 14–15. It is not a measured result from the photographed installation.

Assumptions: 10,000 luminaires, 11 operating hours per day, 365 days per year and an illustrative electricity price of RMB 0.86/kWh. The dimmed case assumes a 70 W average input over those operating hours.

Annual result100 W LED baselineAssumed 70 W average with dimming
Electricity consumption4,015,000 kWh2,810,500 kWh
Electricity costRMB 3,452,900RMB 2,417,030

The calculated annual reduction is 1,204,500 kWh (30%) and RMB 1,035,870. Annual consumption = quantity × average input watts ÷ 1,000 × operating hours. Annual electricity cost = annual consumption × electricity price.

These figures are recalculated from the stated assumptions rather than copied from the brochure’s inconsistent totals. The brochure’s combined 75% claim includes a lamp-replacement comparison and must not be attributed to a receptacle or controller alone.

Applying the example to a project

Actual savings depend on the load, driver dimming response, operating schedule, required illumination, metering boundary and control-system consumption. Confirm electrical compatibility, wiring, orientation and sealing against the applicable installation instructions. Compare measured consumption under equivalent lighting-service conditions before claiming project savings. A receptacle alone does not provide the dimming strategy.

Source: UMELINK SMART LIGHT SOLUTION 2019, pages 14–15 (historical illustrative assumptions; not a current project measurement report). No maintenance-cost or carbon-reduction totals are claimed here.

Explore NEMA receptacles and accessories, smart lighting controls and selection and installation FAQs.

Facebook
Twitter
LinkedIn
WhatsApp
Picture of Wang Yi

Wang Yi

Hello, I'm the author of the post, With 15 years in the lighting industry, I'm passionate about innovation and connection. Join me in exploring industry insights and shaping the future. Let's illuminate together!

You are welcome to Follow me

Close-up of a photocontrol and mating receptacle assembly secured to a metal pole in Chiang Rai, Thailand.