Bedradingsschema van een fotocel - Bedrading van een schemeringssensor

Photocell Sensor Wiring Diagram Instruction

Different Types 0f Photocell Sensor’s Wiring Diagram Instruction

JL-103

Direct Wire-in Thermal Photocontrol (Traditional Button Type)

Installatie

Disconnect power, remove junction box cover, place the SWITCH in knockout hole and fasten with lock-nut.

Wire according to the diagram:(photocell wiring diagram)

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.

JL-104

Direct Thermal Photocontrol(Swivel integrated)

Installatie

Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.

Wire according to the diagram:

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.

JL-106

Direct Wire-in Thermal Photocontrol

JL-106

Installatie

Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.

Wire according to the diagram:

Slide the shading strip to have preferred On/Off levels, if necessary.

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.

JL-118A

Direct Wire-In Thermal photocontrol

Installatie

Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.

Wire according to the diagram:

Slide the shading strip to have preferred On/Off levels, if necessary.

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.

JL-126

Direct Wire-in Thermal Photocontrol(Aluminum Die-cast

Enclosure heavy duty )

Installatie

Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.

Wire according to the diagram:

Slide the shading strip to have preferred On/Off levels, if necessary.

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.

JL-202

Thermal Photocontrol

NEMA Twist-lock

Installatie

Disconnect power; wire the color coded receptacle according to the diagram below.

Druk de fotocel aan en draai hem met de klok mee om hem in de houder te vergrendelen.

Adjust the receptacle position if necessary, to ensure the Photocell facing the NORTH direction as indicated on the top of the photocontrol.

JL-205C & JL-205-12D/24D

Electronic Photocontrol Fail-On

Installatie

Disconnect power; wire the color coded receptacle according to the diagram below.

Druk de fotocel aan en draai hem met de klok mee om hem in de houder te vergrendelen.

Adjust the receptacle position if necessary, to ensure the Photocell facing the NORTH direction as indicated on the top of the photocontrol.

JL-207

Digital Electronic Photocontrol (Long life version)

Installatie

Schakel de stroom uit; sluit het stopcontact aan volgens onderstaand schema.

Druk de fotocel aan en draai hem met de klok mee om hem in de houder te vergrendelen.

Installeer de lichtsensor met de fotocel in de richting van het noorden, zoals aangegeven op de bovenkant van de lichtsensor.

Pas indien nodig de positie van het stopcontact aan.

JL-208-IP66

Kortsluitingskap

Installatie

Disconnect power; wire the receptacle according to the diagram below. Push the Shorting

Cap on and twist it clockwise to lock it into the receptacle.

JL-312C

Bulb Holder ControlLER(candelabra)

Installatie

· Disconnect power;

· Screw bulb off from E12 socket;

· Put the light control unit into the E12 socket, and then turn clockwise to tighten;

· Screw bulb into the bulb holder of the unit;

· Connect power; Turn lamp switch ON.

· Avoid to use the unit in an opaque or reflective glass lantern, as well as use in a wet place.

JL-401C/401CR

Direct Wire-In Electronic Photocontrol

Installatie

Disconnect power, place screw thread of the photocontrol in knockout hole and fasten with rubber gasket and lock-nut. Wire according to the diagram in below. Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.

JL-403C

Direct Wire-In Electronic

Installatie

Disconnect power, remove junction box cover, place the photocontrol through knockout hole and fasten with locknut. Wire according to the diagram in below.

Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.

JL-411(R)-12D/24D

Direct Wire-In Electronic Photocontrol(DC)

Installatie

Disconnect power, place screw thread of the photocontrol in knockout hole and fasten with rubber gasket and lock-nut. Wire according to the diagram in below. Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.

JL-428

Conduit Wire-In Digital Photocontrol (Zero cross +FCC)

Installatie

Disconnect power, remove junction box cover, place the photocontrol in knockout hole and fasten with locknut. Wire according to the diagram in right hand.Do not install the photocontrol with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.

JL-712A3 Zhaga Book-18 Zhaga Controller

Bedradingsschema

Installatie

The interface of the product itself has been fool-proof design, the installation only need

to tighten the controller directly to the rotatable base, as shown in Figure clockwise after

insertion.

JL-241/242/243

Smart Dimming Photocontrol

Installatie

Disconnect power; wire the color coded receptacle according to the diagram below.

Druk de fotocel aan en draai hem met de klok mee om hem in de houder te vergrendelen.

Adjust the receptacle position if necessary, to ensure the Photocell facing the NORTH direction as indicated on the top of the photocontrol.

If you need more and more detailed pdf files of all the linked drawings of the products, please feel free to ask us for them!

info@chiswear.com

Heeft u een vervangende fotocel nodig of wilt u een offerte voor een grotere bestelling?
Geef ons uw type stopcontact door (NEMA twist-lock / Zhaga / 2-3 draden), de spanning en het gewenste aantal. Onze engineers reageren binnen 24 uur met prijsopgave en specificaties.
Vraag een gratis offerte aan →
Facebook
Twitter
LinkedIn
WhatsApp
Afbeelding van Wang Yi

Wang Yi

Hallo, ik ben de auteur van dit bericht. Met 15 jaar ervaring in de verlichtingsbranche heb ik een passie voor innovatie en verbinding. Ga met me mee op ontdekkingstocht door de sector en help mee de toekomst vorm te geven. Laten we samen de wereld verlichten!

Je bent van harte welkom om mij te volgen.

Vraag een offerte aan en laat een reactie achter

Geef een reactie

Je e-mailadres wordt niet gepubliceerd. Vereiste velden zijn gemarkeerd met *

Het laatste nieuws

Handmatig

Neem contact met ons op

Wij sturen u de nieuwste Handleiding voor een cloudgebaseerd slim verlichtingsbesturingssysteem

Wilt u onze nieuwe catalogus en een gratis proefmonster ontvangen? Neem dan contact met ons op.