Photocell Sensor Wiring Diagram Instruction
Different Types 0f Photocell Sensor’s Wiring Diagram Instruction
JL-103
Direct Wire-in Thermal Photocontrol (Traditional Button Type)

Installation
Disconnect power, remove junction box cover, place the SWITCH in knockout hole and fasten with lock-nut.
Wire according to the diagram:(photocell wiring diagram)

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.
Direct Thermal Photocontrol(Swivel integrated)

Installation
Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.
Wire according to the diagram:

Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.
Direct Wire-in Thermal Photocontrol
JL-106

Installation
Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.
Wire according to the diagram:

Slide the shading strip to have preferred On/Off levels, if necessary.
Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.
Direct Wire-In Thermal photocontrol

Installation
Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.
Wire according to the diagram:

Slide the shading strip to have preferred On/Off levels, if necessary.
Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.
Direct Wire-in Thermal Photocontrol(Aluminum Die-cast
Enclosure heavy duty )

Installation
Disconnect power, place screw thread of the SWITCH in knockout hole and fasten with rubber gasket and Zinc alloy lock-nut.
Wire according to the diagram:

Slide the shading strip to have preferred On/Off levels, if necessary.
Do not install the switch with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.
Thermal Photocontrol
NEMA Twist-lock

Installation
Disconnect power; wire the color coded receptacle according to the diagram below.
Push the photocontrol on and twist it clockwise to lock it into the receptacle.
Adjust the receptacle position if necessary, to ensure the Photocell facing the NORTH direction as indicated on the top of the photocontrol.

JL-205C & JL-205-12D/24D
Electronic Photocontrol Fail-On

Installation
Disconnect power; wire the color coded receptacle according to the diagram below.
Push the photocontrol on and twist it clockwise to lock it into the receptacle.
Adjust the receptacle position if necessary, to ensure the Photocell facing the NORTH direction as indicated on the top of the photocontrol.

Digital Electronic Photocontrol (Long life version)
Installation
Disconnect power; wire the receptacle according to the diagram below.
Push the photocontrol on and twist it clockwise to lock it into the receptacle.

Install the photocontrol with the Photocell facing the NORTH direction as indicated on the top of the photocontrol.

Adjust the receptacle position if necessary.
Shorting Cap

Installation
Disconnect power; wire the receptacle according to the diagram below. Push the Shorting
Cap on and twist it clockwise to lock it into the receptacle.

JL-312C
Bulb Holder ControlLER(candelabra)

Installation
· Disconnect power;
· Screw bulb off from E12 socket;
· Put the light control unit into the E12 socket, and then turn clockwise to tighten;
· Screw bulb into the bulb holder of the unit;
· Connect power; Turn lamp switch ON.
· Avoid to use the unit in an opaque or reflective glass lantern, as well as use in a wet place.

Direct Wire-In Electronic Photocontrol

Installation
Disconnect power, place screw thread of the photocontrol in knockout hole and fasten with rubber gasket and lock-nut. Wire according to the diagram in below. Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.

JL-403C
Direct Wire-In Electronic

Installation
Disconnect power, remove junction box cover, place the photocontrol through knockout hole and fasten with locknut. Wire according to the diagram in below.
Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.

JL-411(R)-12D/24D
Direct Wire-In Electronic Photocontrol(DC)

Installation
Disconnect power, place screw thread of the photocontrol in knockout hole and fasten with rubber gasket and lock-nut. Wire according to the diagram in below. Do not install the photocontrol with the Photocell facing artificial or reflected light. This may cause the unit to cycle on and off at night.

Conduit Wire-In Digital Photocontrol (Zero cross +FCC)

Installation
Disconnect power, remove junction box cover, place the photocontrol in knockout hole and fasten with locknut. Wire according to the diagram in right hand.Do not install the photocontrol with the Photocell facing artificial or reflected light. This will cause the unit to cycle on and off at night.

JL-712A3 Zhaga Book-18 Zhaga Controller

Wiring diagram

Installation
The interface of the product itself has been fool-proof design, the installation only need
to tighten the controller directly to the rotatable base, as shown in Figure clockwise after
insertion.

JL-241/242/243
Smart Dimming Photocontrol

Installation
Disconnect power; wire the color coded receptacle according to the diagram below.
Push the photocontrol on and twist it clockwise to lock it into the receptacle.
Adjust the receptacle position if necessary, to ensure the Photocell facing the NORTH direction as indicated on the top of the photocontrol.

If you need more and more detailed pdf files of all the linked drawings of the products, please feel free to ask us for them!
info@chiswear.com






